Detecting Visual Dysfunction with a Visual Field Test
A visual field test is an eye examination that can detect dysfunction in central and peripheral vision, which may be caused by various medical conditions such as glaucoma, stroke, brain tumors, or other neurological deficits. visual field testing can be performed clinically by keeping the subject’s gaze fixed while presenting objects at various places within their visual field. Simple manual equipment such as the tangent screen test or the Amsler grid can be used. When dedicated machinery is used, it is called a perimeter. The exam may be performed by a technician in one of several ways. The test may be performed by a technician directly, with the assistance of a machine, or completely by an automated machine. Machine-based tests aid diagnostics by allowing a detailed printout of the patient’s visual field. Other names for this test may include perimetry, Tangent screen exam, Automated perimetry exam, Goldmann visual field exam, or the Humphrey field exam.
Techniques for Testing Visual Field: Confrontation and Perimetry Explained
Here is a list of techniques used to perform this test: – Confrontation visual field exam: The examiner will ask the patient to cover one eye and stare at the examiner. Ideally, when the patient covers their right eye, the examiner covers their left eye, and vice versa. The examiner will then move his hand out of the patient’s visual field and then bring it back in. Commonly, the examiner will use a slowly wagging finger or a hat pin for this. The patient signals the examiner when his hand comes back into view. This is frequently done by an examiner as a simple and preliminary test. – Perimetry: Perimetry or campimetry is one way to systematically test the visual field. It is the systematic measurement of differential light sensitivity in the visual field by the detection of the presence of test targets on a defined background. Perimetry more carefully maps and quantifies the visual field, especially at the extreme periphery of the visual field.

Various Types of Perimetry for Visual Field Testing
The name comes from the method of testing the perimeter of the visual field. Automated perimeters are used widely, and applications include diagnosing disease, job selection, visual competence assessment, school or community screenings, military selection, and disability classifications. Types of perimetry include the tangent screen, the Goldmann perimeter, and automated perimetry. The simplest form of perimetry uses a white tangent screen. Vision is tested by presenting different sized pins attached to a black wand, which may be moved against a black background. This test stimulus may be white or colored. The Goldmann perimeter is a hollow white spherical bowl positioned a set distance in front of the patient. An examiner presents a test light of variable size and intensity. The light may move towards the center from the perimeter, or it may remain in one location.
Comparison of Goldmann and Automated Perimetry for Visual Field Testing
The Goldmann method is able to test the entire range of peripheral vision and has been used for years to follow vision changes in glaucoma patients. However, now automated perimetry is more commonly used. Automated perimetry uses a mobile stimulus moved by a perimetry machine. The patient indicates whether they see the light by pushing a button. The use of a white background and lights of incremental brightness is called “white-on-white” perimetry.
This type of perimetry is the most commonly used in clinical practice and in research trials where loss of visual field must be measured. However, the sensitivity of white-on-white perimetry is low, and the variability is relatively high. As many as 25-50 percent of the photoreceptor cells may be lost before changes in visual field acuity are detected. This method is commonly used for early detection of blind spots. The patient sits in front of a small concave dome in a small machine with a target in the center.
MP-1 Microperimeter: A Computerized Assessment of Visual Field and Macular Function
The chin rests on the machine, and the eye that is not being tested is covered.A button is given to the patient to be used during the exam. The patient is set in front of the dome and asked to focus on the target at the center.A computer then shines lights on the inside of the dome, and the patient clicks the button whenever a light is seen. The computer then automatically maps and calculates the patient’s visual field using a microperimeter.
The microperimeter assesses macular function in a computerized way.A 2012 observational study by Pacella et al. found a significant improvement in both visual acuity and fixation when treating age-related macular degeneration or macular myopic degeneration with biofeedback treatment through MP-1 microperimeter. Methods of stimulus presentation: Static perimetry tests different locations throughout the field one at a time. First, a dim light is presented at a particular location.
Threshold Static Perimetry: Importance and Procedure in Visual Field Testing
If the patient does not see the light, it is made gradually brighter until it is seen. The minimum brightness required for the detection of a light stimulus is called the “threshold” sensitivity level of that location. This procedure is then repeated at several other locations until the entire visual field is tested. Threshold static perimetry is generally done using automated equipment. It is used for rapid screening and follow-up of diseases involving deficits such as scotomas, loss of peripheral vision, and more subtle vision loss. Perimetry testing is important in the screening, diagnosing, and monitoring of various eye, retinal, optic nerve, and brain disorders. Kinetic perimetry uses a mobile stimulus moved by an examiner, such as in Goldmann kinetic perimetry.
Kinetic Perimetry: Mapping Visual Field Sensitivity Boundaries with Test Lights
First, a single test light of constant size and brightness is used. The text should be corrected as follows:The test light is moved towards the center of vision from the periphery until it is first detected by the patient. This is repeated by approaching the center of vision from different directions. Repeating this process enough times will establish a boundary of vision for that target. The procedure is then repeated using different test lights that are larger or brighter than the original test light. In this way, kinetic perimetry is useful for mapping visual field sensitivity boundaries. It may be a good alternative for patients who have difficulty with automated perimetry, either due to difficulty maintaining a constant gaze or cognitive impairment.